lamp capРUse of test probe B of IEC 61032, with a force not exceeding 1 N: no contact with live parts РUse of test probe B of IEC 61032 through openings, with a force of 20N: no contact with live parts Р8.1.2РUse of test probe 13 of IEC 61032, with a force not exceeding 1 N, through openings in class 0 appliances and class II appliances/constructions: no contact with live parts РTest probe 13 also applied through openings in earthed metal enclosures having a non-conductive coating: no contact with live parts Р8.1.3РFor appliances other than class II, use of test probe 41 of IEC 61032, with a force not exceeding 1 N: no contact with live parts of visible glowing heating elements Р8.1.4РAccessible part not considered live if: Р- safety extra-low a.c. voltage: peak value not exceeding 42.4 V