ed by equipment or layout drawings. Work from approved equipment and shop drawings to locate outlet. Р对于具有特殊用途的插座,应按照设备要求或插座示意图指定的位置安装。依据已审核的图纸标示位置安装插座。Р Field quality control 现场质量控制QCРProvide, checking, adjusting and testing operations on the wiring devices installations including the following: 开关插座安装过程中的供货,验收,调整和测试步骤包括如下:РAll wired terminals shall be checked to verify: 应确认所有电线终端设备Рtight connections连接的紧密性Рelectrical continuity 电气连贯性Рearth continuity 接地连贯性Рsize of wires according to circuit rating 根据电流等级来确定用线规格РAbsence of short circuit. 防止短路РOperate each device at least six times. 至少操作各种电器6次以上РAll wiring devices shall be clean before energizing.在通电前所有开关插座要擦干净РRemove all protective films on the trunking parts before leaving the site, unless paint has not been done.Р在离开现场,完成粉刷工作后才能去掉线槽上的保护膜