剪承载力VC493KN598不满足,需要抗剪筋二剪力计算h0555弯起钢筋494mm21AB杆端QAB380.95KN《涵洞》88年管枫年编著P230as0.049Vsb563.88104.7满足规范6.5.5BA杆端QBA-380.95KNe0.0503侧墙BA杆中间0.00KN负弯矩配筋AS1098mm2间距150,直径20mm,20940.200.38AD最大剪力142KN2CD杆端QCD427.23KN2底板砼抗剪承载力VC493KN199满足抗剪要求DC杆端QDC-427.23KNA跨中最大弯矩214KN.mDC杆中间0.00KNh0555mm3DA杆端QDA142.41KNas0.070AD杆端QAD-114.20KNe0.073应<0.550AD杆中间2.22KN跨中钢筋As1598mm2间距150,直径20mm,20940.290.38三杆件各截面弯矩B两端弯矩-171KN.m1AB杆x01.80mh0555MABmax194KN.mas0.0652CD杆x01.80me0.068应<0.550MCDmax214KN.m负弯矩配筋AS1487mm2间距150,直径20mm,20940.270.383DA杆P7.33KN3侧墙X01.83mA跨中最大弯矩-48KN.m负弯矩钢筋MDAmax-48KN.m立墙外侧受拉,最小负弯矩h0555mmas0.016e0.016应<0.550跨中钢筋As346mm2间距150,直径20mm,20940.060.38B两端弯矩M-171KN.m轴力N-427KN偏心距e0=M/N399.89mm偏心距增大系数n1.000构件的计算长度L01.803.24lo/d<8,n=1.0偏心内型判断399.89166.50为大偏心构件配筋计算asb0.40配筋e655As"-7990As'<pmin*bh0,采用下式因而采用以下计算式