n×q)/(n.t)Р4.2 计算管网管道容积Р以管道平均设计流量,依据本规范条文说明3.3.15第6款中图3.3.15-1选取管道内径,按管道内径求出单位长度的内容积,然后依据管网平面图中管段沿程长度求算.Р4.3 选用额定增压压力?Р选用Po=4.3 MPa(绝压)Р4.4 计算全部储存容器气相总容积VoРVo=n.Vb.(1-η/r) (m3)РVb—瓶组容积(m3)Рr---HFC液体密度(Kg/ m3),20℃时为1407 Kg/ m3Р4.5 计算“过程中点”储存容器内压力PmРPm= Po Vo/(Vo+W/2r+VP )Р4.6 计算管路阻力损失Р以管道流量及管道内径,查图2得到△P/L。再乘以计算长度(含沿程长度及管道连接件当量长度)Р4.7 计算管路总损失∑ΔP及高程压力损失PhР高程压头:Р计算喷头工作压力PcРPc =Pm-(∑ΔP±∑Ph)Р验算设计计算结果Р依据规范规定,应满足下列条件:РPc≥0.7 MPa(绝压)РPc≥Pm/2Р4.8 计算结果汇总Р电源室Р始结点Р终结点Р计算长度Р管道内径Р管道数Р容积Р设计流量Р△P/LР压力损失Р高程压差Р中点压力Р工作压力Р1Р2Р10.5Р32Р9Р0Р5.3Р0.0111Р0.1163Р0.0097Р0Р0Р2Р3Р8.02Р65Р1Р0.0133Р26.235Р0.0066Р0.0527Р0Р0Р0Р3Р4Р35.74Р65Р2Р0.1141Р47.7Р0.0217Р0.7758Р0.0331Р0Р0Р4Р5Р7.4Р50Р2Р0.0177Р23.85Р0.0215Р0.159Р0Р0Р0Р5Р6Р4.6Р40Р4Р0.0111Р11.925Р0.0173Р0.0798Р0Р0Р0Р6Р7Р5.58Р32Р8Р0.0161Р5.9625Р0.014Р0.0782Р0Р2.7005Р1.3959